Operation
The unit comes preset from the factory with the relief valve set at 2500 psi.
See the “Adjustment” section on page 16 of this manual for how to change
this setting.
1. Review the Deutz engine manual, Appendix A, for detailed instructions
on start up, shut down and operation of the engine.
2. Check the condition of all hoses. Look for worn or scraped areas, bubbles,
wrinkles or any other indication that the hose may need replacement.
3. Be sure the tank is filled to the proper level with the specified hydraulic
oil. Be sure the shutoff valve to the pump inlet is fully open.
4. Insure the diesel tank has adequate fuel for the intended operations.
Refueling is most safely done with the engine OFF. Clean up any spills.
5. Verify that the equipment to be operated is properly connected to the
power unit as specified in the “Hydraulic Connections” section on page 13.
6. Be sure the equipment being operated is an “open center” hydraulic
circuit. This means that in the neutral position the circuit has full flow from
the inlet to the outlet. If not, a “closed center” adapter must be installed.
7. Verify that cooling air can freely flow through the oil cooler.
8. If disconnected, connect the battery or air supply. Turn the key to the ON
and then the START position on the main enclosure or on the remote
start/stop switch, or pull the "Engine Start" knob for air start units.
9. To turn the unit off, turn the key to OFF or press the “Stop” button.
10. If the power unit shuts down prematurely, verify that there is fuel in the
fuel tank. If this happens repeatedly there is an abnormal condition which
must be found and fixed before continuing operation.