Deutz 1012 Spécifications Page 125

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 282
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 124
Service Training
Page 4.2
Section 67
09.04
yes no
AB
Pressure now between
17.5 and 20 bar.
yes no
yes no
yes no
D
C
Pressure now okay.
Pressure now okay.
Δp is 6 bar minimum.
Fault in variable-dis-
placement pump. Repair
or replace pump.
Fault in left hydraulic
motor. Repair or replace
motor.
Disconnect the HP lines of left hydraulic motor, repeat the test.
Disconnect HP lines of right hydraulic motor, repeat the test.
Fault in right hydraulic
motor. Repair or replace
motor.
Leak in remote control for
left or right hydraulic
motor. Locate and
remedy the fault or renew
the control.
Install a second LP gauge with adapter V at port E of power limiter. Determine
Δp between ports F and E with engine at idling speed