Maintenance Maintenance schedule
30 © 2008
5
Assignment of the DEUTZ maintenance and service schedules to maintenance intervals
EPA-certified engines
The EPA (
E
nvironmental
P
rotection
A
gency) is a US Government organisation for the protection of the environment and human health.
Standard maintenance schedule
D/TCD 914
Stage Activity To be carried out by Maintenance interval every ....... operating hours (oh)
E10 Initial commissioning Authorised specialists When commissioning new or overhauled engines
E20 Daily inspection Operator 1x daily or every 10 operating hours in continuous operation
E30 Maintenance Qualified personnel D 1000
1)
/ TCD 500
1)
E40 Extended maintenance I 1000
E50 Extended maintenance II Authorised specialists 1.500
1)
The lubricating oil load may be high depending on the application. The lubricating oil change interval must be halved here (
27).
Deviations from the standard maintenacne schedule for engines subject to EPA certification
Stage Activity To be carried out by Maintenance interval every ....... operating hours (oh)
E60 Intermediate overhaul Authorised specialists 3.000